TM 9-3950-253-13&P
0067
MANIFOLD INSTALLATION
WARNING
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can cause
lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety goggles and
use product in a well-ventilated area away from open flame. If ingested, keep individual
calm and seek medical attention. DO NOT induce vomiting. If contact with skin or eyes is
made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. When not using adhesive and sealants, ensure container is securely sealed.
Immediately clean up any spilled compound. Failure to follow this warning may cause
injury to personnel. Seek medical attention in the event of an injury.
1.
Apply thread adhesive to four bolts (Figure 7, Item 1).
2.
Install manifold (Figure 7, Item 4), four washers (Figure 7, Item 2), and bolts (Figure 7, Item 1) on mounting
bracket (Figure 7, Item 3).
Figure 7. Manifold.
3.
Connect stow harness (Figure 8, Item 10) to valve (Figure 8, Item 5) and tighten screw (Figure 8, Item 9).
4.
Connect unstow harness (Figure 8, Item 8) to valve (Figure 8, Item 5) and tighten screw (Figure 8, Item 7).
5.
Connect four hydraulic hoses (Figure 8, Item 3) to fittings (Figure 8, Item 4).
6.
Install cover (Figure 8, Item 2) on support bracket (Figure 8, Item 6) and tighten three wing bolts (Figure 8,
Item 1).
03/15/2011Rel(1.10)root(maintwp)wpno(M582066)