TM 9-3950-253-13&P
0070
ADDITIONAL MUX BOX WIRING INSTALLATION
WARNING
During these procedures, personnel are required to work outside the vehicle where there
are several projecting parts, and personnel are required to bend down. Take care when
bending and straightening. A hard hat is required. Failure to follow this warning may result
in injury to personnel. Seek medical attention in the event of an injury.
NOTE
Route and install wires as tagged during removal.
Install new tiedown straps as required.
1.
Route stowage loom harness (Figure 15, Item 10) into Additional MUX box (Figure 15, Item 1).
2.
Connect 1463 wire to position 3 (Figure 15, Item 6) on P7, 1462 wire to position 3 (Figure 15, Item 7) on P8,
1469 wire to position 3 (Figure 15, Item 8) on P9, and 1466 wire to position 3 (Figure 15, Item 9) on P10.
3.
Connect 1465 wire to position 3 (Figure 15, Item 2) on P3, 1467 wire to position 3 (Figure 15, Item 3) on P4,
1468 wire to position 3 (Figure 15, Item 4) on P5, and 1464 wire to position 3 (Figure 15, Item 5) on P6.
4.
Route CAN bus harness (Figure 15, Item 12) into Additional MUX box (Figure 15, Item 1).
5.
Connect brown wire to position 1 (Figure 15, Item 17), red wire to position 2 (Figure 15, Item 18), orange
wire to position 3 (Figure 15, Item 19), and yellow wire to position 4 (Figure 15, Item 20), on P2.
6.
Route CAN bus harness (Figure 15, Item 11) into Additional MUX box (Figure 15, Item 1).
7.
Connect brown wire to position 1 (Figure 15, Item 13), red wire to position 2 (Figure 15, Item 14), orange
wire to position 3 (Figure 15, Item 15), and yellow wire to position 4 (Figure 15, Item 16), on P1.
0070-16
03/15/2011Rel(1.10)root(maintwp)wpno(M582069)