0070
RELAY BOX WIRING INSTALLATION
1.
Route stowage loom harness (Figure 16, Item 16) into Relay box (Figure 16, Item 1).
2.
Connect 1435 wire to position 1 (Figure 16, Item 13) on P12, and 1472 wire to position 2 (Figure 16,
Item 14) on P12.
3.
Connect 1463 wire to position 2 (Figure 16, Item 7) on P7, 1464 wire to position 2 (Figure 16, Item 8) on P8,
1468 wire to position 2 (Figure 16, Item 9) on P9, and 1467 wire to position 2 (Figure 16, Item 10) on P10.
4.
Connect 1471 wire to position 7 (Figure 16, Item 28) on P2, 1466 wire to position 2 (Figure 16, Item 4) on
P4, 1469 wire to position 2 (Figure 16, Item 5) on P5, and 1462 wire to position 2 (Figure 16, Item 6) on P6.
5.
Route stowage latch harness (Figure 16, Item 17) into Relay box (Figure 16, Item 1).
6.
Connect brown wire to position 1 (Figure 16, Item 2), and blue wire to position 2 (Figure 16, Item 3), on P3.
7.
Route CAN bus harness (Figure 16, Item 18) into Relay box (Figure 16, Item 1).
8.
Connect brown wire to position 1 (Figure 16, Item 24), red wire to position 2 (Figure 16, Item 25), orange
wire to position 3 (Figure 16, Item 26), and yellow wire to position 4 (Figure 16, Item 27), on P2.
9.
Route CAN bus harness (Figure 16, Item 15) into Relay box (Figure 16, Item 1).
10.
Connect brown wire to position 1 (Figure 16, Item 11), and red wire to position 2 (Figure 16, Item 12) on
P11.
11.
Connect orange wire to position 1 (Figure 16, Item 19), yellow wire to position 2 (Figure 16, Item 20), green
wire to position 3 (Figure 16, Item 21), blue wire to position 4 (Figure 16, Item 22), and lilac wire to position 7
(Figure 16, Item 23) on P1.