TM 10-3930-675-20-1
0009 00-1
COOLING FAN OPERATION AND FAN CONTROL TROUBLESHOOTING
0009 00
THIS WORK PACKAGE COVERS
Error Code 166 - Cooling Fan Speed, Wiring Circuit
Failure
Error Code 167 - Cooling Fan Speed, Short Circuit Fail-
ure
Error Code 426 - Fording Level Switch, Input Read
Incorrect
INITIAL SETUP
References
TM 10-3930-675-10
Current Supply (A34738.0200) (WP 0199 00-31)
ECS Electrical Servo (A34648.0200) (WP 0199 00-5)
NOTE
Refer to WP 0004 00 for additional troubleshooting guidance, information, and illustrations
that locate critical components.
Refer also to illustration at end of work package for component location.
Table 1. Error Code 166 - Cooling Fan Speed, Wiring Circuit Failure Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 166 - Cooling Fan Speed, Wiring
Circuit Failure
1. Disconnect connector 6037 at
fan
control
valve,
turn
ignition
switch
to
ON
position and perform voltage
check.
If 20-25V is present at connector
6037, replace fan control valve
(WP 0174 00).
2. Check voltage between con-
nector X158 pin 9 and pin 10.
a. If voltage is present, check
continuity between con-
nector 6037 pin 1 and
connector X158 pin 9 and
between connector 6037
pin 2 and connector X158
pin 10.
If continuity is not present,
repair or replace connectors (WP
0111 00).
TEST OR INSPECTION-
DIAG SERVO
11(13)
OUTPUT/INPUT
FAN 0mA 0mA
BL.VALVE 0.00V 0mA