TM 10-3930-675-20-1
0009 00-3
COOLING FAN OPERATION AND FAN CONTROL TROUBLESHOOTING - CONTINUED
0009 00
Table 2. Error Code 167 - Cooling Fan Speed, Short Circuit Failure Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 167 - Cooling Fan Speed, Short
Circuit Failure
1. Disconnect connector 6037 at
fan control valve. Error code
166 will be displayed.
2. Turn ignition switch to ON
position and perform voltage
check.
If 20-25V are present at connector
6037, replace fan control valve
(WP 0174 00).
3. Disconnect
ECU
(790)
connector
2
and
check
continuity between connector
pin 13 and connector X158 pin
10.
a. If no continuity between pins,
repair or replace connector
(WP 0111 00).
b. If continuity is present, notify
SRA.
4. Disconnect connector X158
and check continuity between
connector 6037 pin 1 and pin 2
and between pin 1 and chassis
and pin 2 and chassis.
a. If continuity is present, repair
or replace connectors (WP 0111
00).
b. If wiring harness must be
replaced, notify SRA.
5. Disconnect
ECU
(790)
connector
2
and
check
continuity between connector
6037 pin 1 and pin 2 and
between connector 6037 pin 1
and chassis and pin 2 and
chassis.
If continuity is present, notify
SRA.
6. Enter DIAG SERVO 11(13)
menu and check current of
FAN
OUTPUT.
Current
should be present.
a. If current is not present, replace
ECU (790) (WP 0079 00).
b.If current is present, notify
SRA.
Table 3. Error Code 426 - Fording Level Switch, Input Read Incorrect Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 426 - Fording Level Switch, Input
Read Incorrect
1. Enter
DIAG
EXTRA
FUNCT 4 (13) menu and
check water level sensor
setting. Enter 0 shut off and
1 to run cooling pump. Check
if fording water level sensor is
clogged or damaged.
Clean and/or replace fording
water level sensor (WP 0090 00).
2. Check
continuity
between
connector X195 pin 12 and
connector X198 pin 8.
a. If no continuity between pins,
repair or replace connectors
(WP 0111 00).
b. If continuity (short) to chassis,
repair or replace connectors
(WP 0111 00).
c. If problem continues, notify
SRA.
DIAG SERVO
11(13)
OUTPUT/INPUT
FAN 0mA 0mA
BL.VALVE 0.00V 0mA