TM 10-3930-675-20-10009 00-3COOLING FAN OPERATION AND FAN CONTROL TROUBLESHOOTING - CONTINUED0009 00Table 2. Error Code 167 - Cooling Fan Speed, Short Circuit Failure Troubleshooting Procedures.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONError Code 167 - Cooling Fan Speed, ShortCircuit Failure1. Disconnect connector 6037 atfan control valve. Error code166 will be displayed.2. Turn ignition switch to ONposition and perform voltagecheck.If 20-25V are present at connector6037, replace fan control valve(WP 0174 00).3. Disconnect ECU (790)connector 2 and checkcontinuity between connectorpin 13 and connector X158 pin10.a. If no continuity between pins,repair or replace connector(WP 0111 00).b. If continuity is present, notifySRA.4. Disconnect connector X158and check continuity betweenconnector 6037 pin 1 and pin 2and between pin 1 and chassisand pin 2 and chassis.a. If continuity is present, repairor replace connectors (WP 011100).b. If wiring harness must bereplaced, notify SRA.5. Disconnect ECU (790)connector 2 and checkcontinuity between connector6037 pin 1 and pin 2 andbetween connector 6037 pin 1and chassis and pin 2 andchassis.If continuity is present, notifySRA.6. Enter “DIAG SERVO 11(13)”menu and check current ofFAN OUTPUT. Currentshould be present.a. If current is not present, replaceECU (790) (WP 0079 00).b.If current is present, notifySRA.Table 3. Error Code 426 - Fording Level Switch, Input Read Incorrect Troubleshooting Procedures.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONError Code 426 - Fording Level Switch, InputRead Incorrect 1. Enter “DIAG EXTRAFUNCT” 4 (13) menu andcheck water level sensorsetting. Enter “0” shut off and“1” to run cooling pump. Checkif fording water level sensor isclogged or damaged.Clean and/or replace fordingwater level sensor (WP 0090 00).2. Check continuity betweenconnector X195 pin 12 andconnector X198 pin 8.a. If no continuity between pins,repair or replace connectors(WP 0111 00).b. If continuity (short) to chassis,repair or replace connectors(WP 0111 00).c. If problem continues, notifySRA.DIAG SERVO11(13)OUTPUT/INPUTFAN 0mA 0mA BL.VALVE 0.00V 0mA
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business