0010 00-1
OVERLOAD PROTECTION TROUBLESHOOTING
0010 00
THIS WORK PACKAGE COVERS
Error Code 130 - Overload Protection System Failure
Error Code 131 - Boom Extension Sensor or Circuit
Failure
Error Code 132 - Boom Angle Sensor or Circuit Failure
Error Code 133 - Left Lift Cylinder Pressure Sensor or
Circuit Failure
Error Code 134 - Right Lift Cylinder Pressure Sensor or
Circuit Failure
Error Code 135 - Left Lift Cylinder Piston Pressure Sen-
sor or Circuit Failure
Error Code 136 - Right Lift Cylinder Piston Pressure
Sensor or Circuit Failure
Error Code 210 - Tophandler Angle Sensor or Circuit
Failure
INITIAL SETUP
References
TM 10-3930-675-10
Current Supply (A34738.0200) (WP 0199 00-31)
ECS Attachment (A34652.0200) (WP 0199 00-23)
ECS Electrical Servo (A34648.0200) (WP 0199 00-5)
NOTE
•
Refer to WP 0004 00 for additional troubleshooting guidance, information, and illustrations
that locate critical components.
•
Refer also to illustrations at end of work package for component location.
Table 1. Error Code 130 - Overload Protection System Failure Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 130 - Overload Protection System
Failure
Overload protection system is
not working due to an earlier
failure (error codes 131-136) on
any component related to the
overload protection system.
Hydraulic speeds are limited and
the error code will flash on the
display every 5 seconds.
Troubleshoot
original
error
codes 131-136.
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business