Table 2. Error Code 1441 - Unswitched Battery Supply Circuit Failure Troubleshooting Procedures
TM-10-3930-675-20-1 Rough Terrain Container Handler (RTCH): RT 240; 53 000 Lb Capacity; 4x4 Manual
Page Navigation
384
385
386
387
388
389
390
391
392
393
394
TM 10-3930-675-20-1
0025 00-6
ENGINE BATTERY VOLTAGE CIRCUITS TROUBLESHOOTING - CONTINUED
0025 00
Table 1. Error Code 1434 - Unswitched Battery Supply Circuit Failure Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 1434 - Unswitched Battery Supply
Circuit Failure - Continued
a. Measure resistance from
OEM harness connector
pin 7 to all other pins in
connector
except
pins 7,
17, 18, and 28.
b. Measure
resistance
from
OEM harness connector pin
8 to all other pins in
connector
except
pins 7,
17, 18, and 28.
c. Measure resistance from
OEM harness connector pin
17 to all other pins in
connector
except
pins 7, 8,
18, and 28.
d. Measure resistance from
OEM harness connector pin
18 to all other pins in
connector
except
pins 7, 8,
17, and 28.
e. Measure
resistance
from
OEM harness connector pin
28 to all other pins in
connector
except
pins 7, 8,
17, and 18.
>100K OHMS
USE TEST
LEAD KIT P/N 3822758
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business