Error Code 1441 - Unswitched Battery Supply Circuit Failure - Cont - TM-10-3930-675-20-1_429
Table 3. Error Code 1442 - Unswitched Battery Supply Circuit Failure Troubleshooting Procedures
TM-10-3930-675-20-1 Rough Terrain Container Handler (RTCH): RT 240; 53 000 Lb Capacity; 4x4 Manual
Page Navigation
388
389
390
391
392
393
394
395
396
397
398
TM 10-3930-675-20-1
0025 00-10
ENGINE BATTERY VOLTAGE CIRCUITS TROUBLESHOOTING - CONTINUED
0025 00
Table 2. Error Code 1441 - Unswitched Battery Supply Circuit Failure Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 1441 - Unswitched Battery Supply
Circuit Failure - Continued
e. Measure
resistance
from
OEM harness connector pin
28 to all other pins in
connector
except
pins 7, 8,
17, and 18.
>100K
OHMS
USE TEST
LEAD KIT P/N 3822758
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business