TM 10-3930-675-20-1
0025 00-16
ENGINE BATTERY VOLTAGE CIRCUITS TROUBLESHOOTING - CONTINUED
0025 00
Table 4. Error Code 1474 - Starter
Solenoid
Lockout
Relay
Driver Circuit Failure
Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 1474 - Starter
Solenoid
Lockout
Relay
Driver Circuit Failure - Continued
10.Ensure that ignition switch is
in OFF position. Disconnect
actuator harness connector
from 31-pin connector and
disconnect XK12 connector
from relay board.
11.Measure
resistance
from pin
20 on harness side of 31-pin
connector to all other pins in
connector. Resistance should
be greater than 100k ohms.
If
resistance
is not as specified,
notify SRA to repair or replace
engine harness.
12.Ensure that ignition switch is
in OFF position. Disconnect
actuator harness connector
from 31-pin connector and
disconnect XK12 connector
from relay board.
>100K OHMS
USE TEST LEAD KIT P/N
3822758
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business