TM 10-3930-675-20-2
0076 00-2
TOPHANDLER JUNCTION BOX MAINTENANCE - CONTINUED
0076 00
TOPHANDLER ELECTRONIC CONTROL UNIT (ECU) REMOVAL - CONTINUED
NOTE
Perform step 3 for each of three connectors.
Tag connectors for installation.
3.
With a flat-tip screwdriver, slide red latch segment (7) of connector away from black connector (6) and remove connec-
tor from tophandler ECU (10).
4.
Remove four screws (8), washers (9), and tophandler ECU (10) from tophandler junction box (4).
TOPHANDLER ELECTRONIC CONTROL UNIT (ECU) INSTALLATION
CAUTION
Do NOT overtighten screws or damage to screws will result.
1.
Install tophandler ECU (10) in tophandler junction box (4) with four washers (9) and screws (8).
NOTE
Perform step 2 for each of three connectors.
2.
Position black connector (6) to tophandler ECU (10) and connect connector by sliding red latch segment (7) of connec-
tor inward.
3.
Install cover (2) on tophandler junction box (4) and tighten six screws (1).
4.
Perform boom and tophandler calibration (WP 0197 00).
10
6
7
8,9
4