TM 10-3930-675-20-20077 00-3TOPHANDLER PROXIMITY SWITCH JUNCTION BOXES REPLACEMENT - CONTINUED0077 00INSTALLATION - CONTINUEDNOTEPerform step 2 in five places.2.Install fitting (10) and plastic nut (11) to bottom of junction box (3).3.Install terminal blocks (7) and terminal block holder (6) to junction box (3) with two screws (5).NOTEPerform steps 4 and 5 in five places.4.Push cable (12) into junction box (3) and use jeweler’s screwdriver to connect wires (8) to terminal blocks (7).5.Install grommet (13) and cable nut (14) to junction box (3). Tighten cable nut.6.Install cover (2) to junction box (3) with four screws (1).7.Perform boom and tophandler calibration (WP 0197 00).END OF WORK PACKAGE1234