TM 10-3930-675-20-2
0099 00-3
BOOM EXTENSION SENSOR REPLACEMENT - CONTINUED
0099 00
INSTALLATION
1.
Install boom extension sensor (8) to boom (4) with two washers (10) and screws (9).
2.
Connect connector (11) of wiring harness to boom extension sensor (8).
3.
Extend ring of cable (7) from boom extension sensor (8).
4.
Install ring of cable (7) to rear of extension boom (6) with cable connector (5). Close cable connector.
5.
Install cover plate (1) to rear of boom (4) with two washers (3) and screws (2).
6.
Perform boom and tophandler calibration (WP 0197 00).
END OF WORK PACKAGE
1
2,3
4