TM 10-3930-675-20-20100 00-2TOPHANDLER ANGLE SENSOR REPLACEMENT - CONTINUED0100 00REMOVAL - CONTINUED2.Loosen setscrew (7) of lever (9) and remove lever from tophandler angle sensor (4).3.Remove three screws (5), washers (6), and bracket (8) from tophandler angle sensor (4).4.Remove three screws (16), washers (17), cable (15), and cable clamps (18) from boom extension.5.Loosen cable nut (14) and slide cable nut and grommet (13) back on cable (15) of tophandler angle sensor.6.Loosen six screws (10) and remove cover (11) from tophandler junction box (12). Inspect rubber seal in groove of cover.Replace only if damaged.5,67894