TM 10-3930-675-20-2
0170 00-1
BOOM FOLDING CONTROL VALVE REPLACEMENT
0170 00
THIS WORK PACKAGE COVERS
Removal, Installation
INITIAL SETUP
Tools and Special Tools
Tool kit, general mechanics (Item 31, WP 0204 00)
Pan, drain (Item 20, WP 0204 00)
Materials/Parts
Cap set, protective (Item 4, WP 0203 00)
Oil, lubricating (Item 19, WP 0203 00)
Rag, wiping (Item 22, WP 0203 00)
Strap, tiedown (Item 27, WP 0203 00)
Tag, marker (Item 28, WP 0203 00)
References
LO 10-3930-675-12
WP 0183 00
WP 0194 00
Equipment Condition
Hydraulic system pressure relieved (WP 0164 00)
Master battery switch in OFF position
WARNING
DO NOT disconnect or remove any hydraulic system line or fitting unless hydraulic system pressure
has been relieved. Tighten all connections before applying pressure. Escaping hydraulic fluid under
pressure can penetrate the skin, causing serious injury.
Search for leaks with a piece of cardboard. Protect hands and body from high-pressure fluids. If an acci-
dent occurs, see a doctor immediately. Any fluid injected into the skin must be surgically removed
within a few hours or gangrene may result.
At operating temperature, hydraulic oil is hot. Allow hydraulic oil to cool before disconnecting any
hydraulic lines. Failure to do so could result in injury.
Hydraulic fluid is very slippery. Immediately wipe up any spills. Failure to follow this warning may
result in injury to personnel.
CAUTION
Wipe area clean around all hydraulic connections prior to disconnecting. Cap or plug all openings after dis-
connecting. Contamination of hydraulic system could result in equipment failure.
NOTE
Tag all hydraulic lines.
Remove and discard tiedown straps as necessary to gain free movement in hydraulic hoses.