TM 10-3930-675-20-20191 00-2TOPHANDLER REPLACEMENT - CONTINUED0191 00REMOVAL - CONTINUED7.Disconnect each tilt cylinder (1) from tophandler (5):a.Remove bolt (2) and lockwasher (3). Retain lockwasher.b.Install bolt (2) into threaded hole in pin (4) and screw in to withdraw pin.8.Operate tilt cylinders (1) to fully retract right cylinder and fully extend left cylinder (TM 10-3930-675-10).9.Rest right tilt cylinder (1) on tilt cylinder support and secure. Secure left tilt cylinder to boom by wrapping tiedown straparound boomCAUTIONEnsure electrical connectors are clear and secured to avoid damaging connectors.NOTETag electrical connectors to ensure correct installation.10.Disconnect four electrical connectors (7) from bottom of tophandler junction box (6) and secure.12,345THREADEDHOLE