TM 10-3930-675-20-20190 00-5AIR CONDITIONER FANS MAINTENANCE - CONTINUED0190 00RELAYS AND RESISTORS INSTALLATIONNOTEPerform steps 1 and 2 to install each of two resistors.1.Install resistor (18) to cover (3) with two screws (17), washers (16), and new locknuts (15).2.Connect two connectors (19) of fan wiring harness (9) to resistor (18).NOTEPerform steps 3 and 4 to install two fan relays.3.Install terminal blocks (14) of fan wiring harness (9) to cover (3) with two screws (13), washers (12), and new locknuts(11).4.Install two relays (10) to terminal blocks (14).5.Install position cover (3) assembly to condenser fan box (1) and install ten screws (2).END OF WORK PACKAGE123