TM 10-3930-675-20-2
0194 00-6
GENERAL MAINTENANCE INSTRUCTIONS - CONTINUED
0194 00
Table 2. Flat Face Type O-Rings (ORS).
3.
Connect hydraulic hose and use a crowfoot attachment set (Item 5, WP 0204 00) and appropriate torque wrench to
tighten the connection.
4.
Table 3 provides torque range in relation to size of hydraulic hose fitting.
Table 3. Hydraulic Hose Torque Chart.
CAUTION
Following any hydraulic system maintenance that results in hydraulic system being opened, replacement of
hydraulic reservoir return filters is required after 100 hours of operation.
5.
Replace hydraulic reservoir return filters after 100 hours of operation (WP 0183 00).
FLUID DISPOSAL
Dispose of contaminated drained fluids in accordance with the Standard Operating Procedures (SOP) of your unit.
END OF WORK PACKAGE
DIMENSIONS
(I.D. x W)
SAE No.
KRTC P/N
KRTC P/N
QTY PER KIT
0.301 x 0.070
J515 Type 1
-011
12J1047
10
0.364 x 0.070
J515 Type 1
-012
12J1048
10
0.489 x 0.070
J515 Type 1
-014
12J1049
10
0.614 x 0.070
J515 Type 1
-016
12J1050
10
0.739 x 0.070
J515 Type 1
-018
12J1051
10
0.926 x 0.070
J515 Type 1
-021
12J1052
5
1.176 x 0.070
J515 Type 1
-025
12J1053
5
1.489 x 0.070
J515 Type 1
-029
12J1054
5
WIDTH ACROSS FLATS IN MM
TORQUE RANGE
18
17-18 lb-ft (23-25 Nm)
21
24-28 lb-ft (33-38 Nm)
24
38-42 lb-ft (51-57 Nm)
29
59-66 lb-ft (80-90 Nm)
35
88-96 lb-ft (120-130 Nm)
41
111-125 lb-ft (150-170 Nm)
48
133-147 lb-ft (180-200 Nm)
51
147-177 lb-ft (200-240 Nm)