TM 10-3930-675-24-2
HYDRAULIC RESERVOIR AND LIFT CYLINDER SENSORS REPLACEMENT - CONTINUED
0102 00
LIFT CYLINDER SENSOR REPLACEMENT
1.
Disconnect electrical connector (11) from sensor (12).
2.
Remove sensor (12) and O-ring from locking valve (14) at base of lift cylinder (13). Discard O-ring.
NOTE
Replacement sensor comes with new O-ring.
3.
Lubricate new O-ring with lubricating oil. Install O-ring and sensor (12) to locking valve (14). Tighten sensor to 35 lb-ft
(47 Nm).
11
12
13
14
4.
Connect electrical connector (11) to sensor (12).
5.
END OF WORK PACKAGE