TM 10-3930-675-24-2
HYDRAULIC FILTER INDICATOR SENSORS REPLACEMENT - CONTINUED
0103 00
REMOVAL - CONTINUED
3.
Loosen cable nut (10) and slide cable nut and grommet (9) back on cable (3).
4.
Using a jeweler's screwdriver, disconnect cable wires (8) from terminal blocks (7). Remove cable (3) from junction box
(6).
6
7
8
9
10
3
5.
Remove sensor (4) with cable (3) from filter head (5).
INSTALLATION
NOTE
Use electrically conductive grease on wire connections before connections are made.
Install new tiedown straps as necessary.
1.
Install sensor (4) on filter head (5).
2.
Feed cable (3) through grommet (9) and cable nut (10) and into junction box (6).
3.
Using a jeweler's screwdriver, connect cable wires (8) to terminal blocks (7).
4.
Install grommet (9) and cable nut (10) on junction box (6). Tighten cable nut.
5.
Install cover (1) on junction box (6) and tighten four screws (2).
6.
7.
Return cab to operational position (TM 10-3930-675-10).
END OF WORK PACKAGE
0103 00-3/(0103 00-4 Blank)