TM 5-3810-306-34
OIL PUMP INSTALLATION
EQUIPMENT CONDITIONS: Negative battery cable disconnected at shunt.
(Refer to TM 5-3810-306-20.)
REMOVAL:
1. REMOVE LUBE OIL PUMP.
a. Remove four capscrews (2).
b. Remove lube oil pump (1).
2. REMOVE BACK PLATE (3).
3. MARK "TOP" ON GEROTOR PLANETARY (5
AND REMOVE.
CLEANING AND INSPECTION
WARNING
Dry cleaning solvent P-D-
680 is toxic and flammable.
Wear protective goggles
and gloves and use only in
a well ventilated area.
Avoid contact with skin,
eyes, and clothes and don't
breathe vapors. Do not use
near
open
flame
or
excessive heat. The flash
point is 100F-138F (380-
590C). If you become dizzy
while
using
cleaning
solvent,
get
fresh
air
immediately
and
get
medical aid. If contact with
eyes is made, wash your
eyes with water and get
medical aid immediately.
4-59