TM 9-3950-253-13&P
0072
INSTALLATION
WARNING
Use caution when using adhesives and sealants. Prolonged inhalation of vapors
can cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and
safety goggles and use product in a well-ventilated area away from open flame. If
ingested, keep individual calm and seek medical attention. DO NOT induce
vomiting. If contact with skin or eyes is made, flush thoroughly with water. Dispose
of cleanup rags IAW local policy and ordinances.
When not using adhesive and sealants, ensure container is securely sealed.
Immediately clean up any spilled compound.
Component will fall when attaching hardware is removed. Support component
while installing attaching hardware.
Failure to follow these warnings may result in injury to personnel. Seek medical
attention in the event of an injury.
1.
Apply thread adhesive to four shoulder bolts (Figure 1, Item 2).
WARNING
Use extreme caution when handling heavy parts. Provide adequate support and use
assistance during procedure. Failure to follow this warning may result in injury or death to
personnel. Seek medical attention in the event of an injury.
NOTE
Bail bar weighs 61 lb (28 kg).
2.
With assistance, install bail bar (Figure 1, Item 3), four shoulder bolts (Figure 1, Item 2), and new locknuts
(Figure 1, Item 4) on lift frame (Figure 1, Item 1). Tighten locknuts to 147 lb-ft (200 Nm).
END OF TASK
FOLLOW-ON MAINTENANCE
END OF TASK
END OF WORK PACKAGE
0072-3/blank
03/15/2011Rel(1.10)root(maintwp)wpno(M582071)