TM 10-3930-675-20-2
0101 00-4
HYDRAULIC RESERVOIR AND LIFT CYLINDER SENSORS REPLACEMENT - CONTINUED
0101 00
LIFT CYLINDER SENSOR REPLACEMENT
1.
Disconnect electrical connector (10) from sensor (11).
2.
Remove sensor (11) and o-ring from locking valve (13) at base of lift cylinder (12). Discard o-ring.
NOTE
Replacement sensor comes with new o-ring.
3.
Lubricate new o-ring with lubricating oil. Install o-ring and sensor (11) to locking valve (13). Tighten sensor to 35 lb-ft
(47 Nm).
4.
Connect electrical connector (10) to sensor (11).
5.
Calibrate boom and tophandler (WP 0197 00).
END OF WORK PACKAGE
13
12
11
10