TM 10-3930-675-20-20101 00-3HYDRAULIC RESERVOIR AND LIFT CYLINDER SENSORS REPLACEMENT - CONTINUED0101 00PRESSURE SENSOR REPLACEMENT1.Remove four socket head screws (6) from flange (7).2.Remove flange (7), sensor (5), and o-ring (8) from hydraulic reservoir (3). Discard o-ring.3.Trace sensor cable (9) back to junction box. Disconnect wires of cable from terminal blocks. Remove cable from junc-tion box.NOTEReplacement sensor comes with new o-ring.4.Lubricate new o-ring (8) with lubricating oil. Install o-ring and sensor (5) to hydraulic reservoir (3) with flange (7) andfour socket head screws (6).5.Position sensor cable (9) to junction box. Connect wires of sensor cable to terminal blocks of junction box.6.Secure sensor cable (9) with new tiedown straps.3567,89