TM 10-3930-675-20-20101 00-2HYDRAULIC RESERVOIR AND LIFT CYLINDER SENSORS REPLACEMENT - CONTINUED0101 00TEMPERATURE SENSOR REPLACEMENT1.Drain hydraulic reservoir (WP 0184 00).2.Disconnect connector (2) of temperature sensor (4) from wiring harness (1).3.Remove temperature sensor (4) and four copper washers from hydraulic reservoir (3).4.Install four copper washers and hydraulic temperature sensor (4) to hydraulic reservoir (3).5.Connect connector (2) of temperature sensor (4) to wiring harness (1).6.Fill hydraulic reservoir (WP 0184 00).1234