TM 10-3930-675-20-2
0101 00-2
HYDRAULIC RESERVOIR AND LIFT CYLINDER SENSORS REPLACEMENT - CONTINUED
0101 00
TEMPERATURE SENSOR REPLACEMENT
1.
Drain hydraulic reservoir (WP 0184 00).
2.
Disconnect connector (2) of temperature sensor (4) from wiring harness (1).
3.
Remove temperature sensor (4) and four copper washers from hydraulic reservoir (3).
4.
Install four copper washers and hydraulic temperature sensor (4) to hydraulic reservoir (3).
5.
Connect connector (2) of temperature sensor (4) to wiring harness (1).
6.
Fill hydraulic reservoir (WP 0184 00).
1
2
3
4