TM 10-3930-675-20-2
0054 00-2
OIL SAMPLING VALVES AND HOSES REPLACEMENT - CONTINUED
0054 00
OIL SAMPLING VALVE REMOVAL - CONTINUED
1.
Hold fitting jam nut in place and disconnect engine oil sampling valve from fitting.
2.
Cap fitting with protective cap.
OIL SAMPLING VALVE INSTALLATION
1.
Remove protective cap and install oil sampling valve.
2.
Start engine (TM 10-3930-675-10) and check for oil leaks.
ENGINE OIL SAMPLING VALVE HOSE REMOVAL
NOTE
Tag and trace routing of oil sampling valve hose prior to disconnecting.
1.
Remove tiedown straps and clamps as necessary. Discard tiedown straps.
2.
Disconnect hose from oil sampling valve fitting and engine fitting. Remove hose.
3.
Remove engine fitting.
ENGINE OIL
SAMPLING
VALVE
TRANSMISSION OIL
SAMPLING VALVE
HYDRAULIC SYSTEM
OIL SAMPLING VALVE