TM 55-8145-202-14
3-3.
TROUBLESHOOTING TABLE.
Table 3-1. Operator Troubleshooting Instructions.
WARNING
Be sure to read ALL Warnings in front of manual before troubleshooting.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
REAR DOORS WILL NOT CLOSE.
Step 1. Verify that left rear door was closed before right door.
Close left door, then right door.
Step 2. Inspect for cargo, rocks, or packaging material between doors and container frame.
Remove obstructions from container opening.
Step 3. Inspect for bent, broken, or twisted door latch hardware.
Notify Unit Maintenance.
2.
WATER WILL NOT DRAIN FROM CONTAINER FLOOR.
Step 1. Check for clogged floor drain screens.
Clear floor drain screens.
NOTE
Drain hose is flat. Do not mistake flat hose for kinks.
Step 2. Check for kinked, twisted, flat surfaces sticking together or folded drain hoses under corners of container.
Straighten drain hose. Hose should hang straight down.
3.
TEMPERATURE RECORDER DOES NOT RECORD OR DOES NOT RECORD PROPERLY.
Step 1. Verify that temperature recorder has been wound.
Step 2. Check for loose knurled nut securing paper chart to recorder platen.
Tighten knurled nut.
Step 3. Check that stylus is in contact with paper chart.
If stylus is bent, damaged or defective, notify unit maintenance.
3-2