1.
Loosely install two bolts (Figure 10, Item 4) in cable clamp (Figure 10, Item 2) and insert twistlock sensor
(Figure 10, Item 3) into clamp.
NOTE
Verify that sensor is perpendicular to twistlock plate.
2.
Adjust twistlock sensor (Figure 10, Item 3) placement until end of sensor is 0.0625 to 0.1875 in. (2 to 3 mm)
from twistlock plate (Figure 10, Item 4) and tighten two bolts (Figure 10, Item 4) in cable clamp (Figure 10,
Item 2).
3.
Connect electrical connector (Figure 10, Item 1) to twistlock sensor (Figure 10, Item 3).
Figure 10. Twistlock Sensor.
END OF TASK