PALLETIZED LOAD SYSTEM TRUCK, M1075 AND M1075A1 (PLS) AND HEAVY EXPANDED MOBILITY TACTICAL TRUCK, M1120, M1120A2, AND M1120A4 ENHANCED CONTAINER HANDLING UNIT
Page Navigation
  344    345    346    347    348  349  350    351    352    353    354  
img
.
TM 9-3950-253-13&P
0075
MIDDLE FRAME SENSOR INSTALLATION AND CALIBRATION - Continued
NOTE
It may be necessary to adjust position of sensor plate in order to activate sensor light.
4.
Adjust nut (Figure 13, Item 4) until face of sensor (Figure 13, Item 1) is 0.0625 to 0.1875 in. (2 to 3 mm)
from sensor plate (Figure 13, Item 6).
5.
Slide middle frame sensor (Figure 13, Item 1) on bracket (Figure 13, Item 3) toward sensor plate (Figure 13,
Item 6) and identify position where sensor light (Figure 13, Item 5) turns on. Tighten nut (Figure 13, Item 2)
at that position.
6.
Return hook arm to stowed position (PLS: TM 9-2320-364-14&P, HEMTT: TM 9-2320-326-14&P).
Figure 13. Middle Frame Sensor Calibration.
END OF TASK