TM 10-3930-641-34-2
TORQUE CONVERTER ASSEMBLY (CONT)
(Sheet 8 of 15)
LOCATION/ITEM
ACTION
REMARKS
15. Stator (43)
Install in carrier.
16. Stator ring (41)
Install.
17. Carrier (44) and stator (43)
Install in housing (33).
18. Outer impeller (50) and inner
Check clearance between outer impeller and
impeller (52)
inner impeller.
The difference between dimensions (K) and
(L) must be at least 0.035 - 0.055 in.
(0.64 - 1.40 mm), but no more than 0.60 in.
(1.52 mm). Check in several locations.
The difference between the diameter of the
outer impeller (N) and the diameter of the
inner impeller (M) must be at least .049 -
.065 in. (1.25 - 1.65 mm) but no more than
.086 in. (2.18 mm). Check in several locations.
TA099246
Go on to Sheet 9
4-34