TM 10-3930-675-20-2
0197 00-2
BOOM AND TOPHANDLER CALIBRATION - CONTINUED
0197 00
CALIBRATION - CONTINUED
2.
Boom Calibration, Boom Angle, Lowered Position (Menu 1 of 10).
a.
Lower boom to lowest position.
b.
Allow ECS display to stabilize, then press Enter.
c.
ECS display screen should look like the following:
d.
Press right arrow button to advance thru remaining calibration menus.
3.
Boom Calibration, Tophandler Tilt Position (Menu 2 of 10).
a.
Lower boom to lowest position.
b.
Level tophandler with the ground.
c.
Allow ECS display to stabilize, then press Enter.
d.
ECS display screen should look like the following:
e.
Press right arrow button to advance thru remaining calibration menus.
4.
Boom Calibration, Boom Angle, Raised Position (Menu 3 of 10).
a.
Raise boom to maximum height and fully retract with tophandler level with ground.
b.
Allow ECS display to stabilize, then press Enter.
c.
ECS display screen should look like the following:
d.
Press right arrow button to advance thru remaining calibration menus.
CALIBR SERVO
1 (10)
LOWER
MINIMUM
BOOM ANGLE
XXX
XXX
CALIBR SERVO
2 (10)
LOWER
MINIMUM
TILT ANGLE
XXX
XXX
CALIBR SERVO
3 (10)
LIFT
MAXIMUM
BOOM ANGLE
XXX
XXX
Range 200-400
Range 200-400
Range 600-800