TM 10-3930-675-20-2
0197 00-1
BOOM AND TOPHANDLER CALIBRATION
0197 00
THIS WORK PACKAGE COVERS
Calibration
INITIAL SETUP
References
TM 10-3930-675-10
NOTE
RTCH must be parked on level ground with all wheels pointing straight ahead.
When calibrating the boom and tophandler, perform all ten calibration steps in order. DO NOT skip or
omit any steps.
CALIBRATION
1.
Access to Calibration Menus.
a.
Turn master battery switch to ON position.
b.
Turn ignition switch ON and start truck.
c.
Select Kalmar service menu on drivers Electronic Control System (ECS) display screen and press Enter.
NOTE
If boom or tophandler angle sensors have been removed or are being replaced, steps d-f must be performed
prior to calibration.
d.
Ensure boom and tophandler are level with ground.
e.
Enter diagnostic menus, select DIAG SERVO menu, and scroll down to display 7(13). Note angle sensor voltage
reading.
f.
Loosen setscrew securing angle sensor lever to shaft. Rotate sensor shaft until voltage reading is between 7 and 8
volts (boom angle sensor) or 4 volts (tophandler angle sensor). Retighten setscrew and recheck voltage reading.
g.
Enter calibration program access number 13221 and press Enter.
h.
Press right arrow button to locate CALIBR SERVO menu, then press Enter.