REMOVAL - Continued
Figure 3. PLS M1075 Stowage Control Unit Removal.
3.
Remove four bolts (Figure 4, Item 13) and stowage control unit (Figure 4, Item 1) from backplate (Figure 4,
Item 2).
4.
Remove two locknuts (Figure 4, Item 6), washers (Figure 4, Item 5), bolts (Figure 4, Item 3), washers
(Figure 4, Item 4), and backplate (Figure 4, Item 2) from bracket (Figure 4, Item 11). Discard locknuts.
5.
Remove four locknuts (Figure 4, Item 7), washers (Figure 4, Item 8), bolts (Figure 4, Item 9), washers
(Figure 4, Item 10), and bracket (Figure 4, Item 11) from fender (Figure 4, Item 12). Discard locknuts.
Figure 4. PLS M1075A1 Stowage Control Unit Removal.
END OF TASK