TM 9-3950-253-13&P
0086
INSTALLATION - Continued
HEMTT Stowage Control Unit and Bracket Installation
1.
Install stowage control unit (Figure 7, Item 8), four washers (Figure 7, Item 6), and bolts (Figure 7, Item 5)
on stowage control unit bracket (Figure 7, Item 7).
2.
Install stowage control unit bracket (Figure 7, Item 7), two washers (Figure 7, Item 2), bolts (Figure 7,
Item 1), washers (Figure 7, Item 3), and new locknuts (Figure 7, Item 4) on hydraulic control bracket
(Figure 7, Item 9).
Figure 7. HEMTT Stowage Control Unit Installation.
Stowage Control Unit Harness Installation
NOTE
Route and install wires and harnesses as tagged during removal.
Install new tiedown straps as required.
1.
Route RH twistlock wiring harness (Figure 8, Item 9) into stowage control unit (Figure 8, Item 3) and install
blue, brown, and black wires (Figure 8, Item 7) on connector P10 (Figure 8, Item 6).
2.
Route LH twistlock wiring harness (Figure 8, Item 10) into stowage control unit (Figure 8, Item 3) and install
blue, brown, and black wires (Figure 8, Item 4) on connector P9 (Figure 8, Item 5).
3.
Route CAN bus wiring harness (Figure 8, Item 8) into stowage control unit (Figure 8, Item 3) and install
yellow, orange, red and brown wires (Figure 8, Item 11) on connector P1 (Figure 8, Item 12).
4.
Install cover (Figure 8, Item 2) on stowage control unit (Figure 8, Item 3) and tighten four bolts (Figure 8,
Item 1).
03/15/2011Rel(1.10)root(maintwp)wpno(M582085)